Assessment Year | 2016 |
---|---|
Principal Product | Extruded Rubber Hoses |
NAICS | 326291: Rubber Product Manufacturing for Mechanical Use |
SIC | 3061: Molded, Extruded, and Lathe-Cut Mechanical Rubber Goods |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
420,000
ft2
|
Annual Production | 25,000
thousand feet
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $771,767 | 9,700,800 |
kWh
|
$0.080 |
Electricity Demand | $225,720 | 25,992 |
kW-mo/yr
|
$8.68 |
Electricity Fees | $121,211 | - |
|
- |
Natural Gas | $167,411 | 35,964 |
MMBtu
|
$4.65 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $99,369 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $75,907 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $38,353 | $95,355 |
$29,209
365,109
kWh
|
$9,144
-
kW-mo/yr
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $30,595 | $1,660 |
$17,298
216,224
kWh
|
$13,297
-
kW-mo/yr
|
- | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $8,974 | $40 |
$6,794
84,927
kWh
|
$2,180
-
kW-mo/yr
|
- | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $8,028 | $8,642 |
$6,113
76,412
kWh
|
$1,915
-
kW-mo/yr
|
- | |
05 | 2.7135: Install occupancy sensors | $4,106 | $884 |
$4,106
51,320
kWh
|
- | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $3,562 | $1,832 |
$2,711
33,888
kWh
|
$851
-
kW-mo/yr
|
- | |
07 | 2.2515: Use optimum thickness insulation | $2,670 | $1,810 | - | - |
$2,670
-
MMBtu
|
|
08 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,585 | $670 |
$1,377
17,216
kWh
|
$208
-
kW-mo/yr
|
- | |
09 | 2.7316: Centralize control of exhaust fans to ensure their shutdown, or establish program to ensure manual shutdown | $1,313 | $480 |
$1,009
12,614
kWh
|
$304
-
kW-mo/yr
|
- | |
10 | 2.7134: Use photocell controls | $183 | $480 |
$183
2,288
kWh
|
- | - | |
TOTAL RECOMMENDED | $99,369 | $111,853 |
$68,800
859,998
kWh
|
$27,899
-
kW-mo/yr
|
$2,670
-
MMBtu
|
||
TOTAL IMPLEMENTED | $75,907 | $100,189 |
$50,796
634,941
kWh
|
$22,441
-
kW-mo/yr
|
$2,670
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs