Assessment Year | 1986 |
---|---|
Principal Product | RADIATOR CAPS |
NAICS |
n/a
|
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $10 M to 50M |
# of Employees | 300 |
Plant Area |
n/a
|
Annual Production | 25,000,000
pieces
|
Production Hrs. Annual | 8,064
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $519,508 | 9,775,498 |
kWh
|
$0.053 |
Natural Gas | $30,412 | 7,320 |
MMBtu
|
$4.15 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $10,285 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,851 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.2514: Cover open tanks | $1,590 | $385 |
$1,590
68,875
kWh
|
|
02 | 2.4133: Use most efficient type of electric motors | $1,114 | $1,191 |
$1,114
36,635
kWh
|
|
03 | 2.7261: Install timers and/or thermostats | $619 | $220 |
$619
26,964
kWh
|
|
04 | 2.7446: Utilize sensors controlling roof and wall openings | $217 | $450 |
$217
9,379
kWh
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,320 | $9,000 |
$4,320
79,132
kWh
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,425 | $1,200 |
$2,425
65,944
kWh
|
|
TOTAL RECOMMENDED | $10,285 | $12,446 |
$10,285
286,929
kWh
|
||
TOTAL IMPLEMENTED | $4,851 | $2,255 |
$4,851
171,162
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs