Assessment Year | 2006 |
---|---|
Principal Product | Industrial Quilters |
NAICS | 333249: Other Industrial Machinery Manufacturing |
SIC | 3552: Textile Machinery |
Sales Range | $10 M to 50M |
# of Employees | 160 |
Plant Area |
90,000
ft2
|
Annual Production | 215
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $67,927 | 1,722,276 |
kWh
|
$0.039 |
Electricity Demand | $39,277 | 4,984 |
kW-mo/yr
|
$7.88 |
Electricity Fees | $27,889 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $42,096 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $21,099 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $17,833 | $56,238 |
$11,433
200,850
kWh
|
$6,400
-
kW-mo/yr
|
- | - | |
02 | 2.7221: Lower temperature during the winter season and vice-versa | $14,670 | $84 |
$10,142
182,277
kWh
|
$4,528
-
kW-mo/yr
|
- | - | |
03 | 2.8121: Apply for tax-free status for energy purchases | $3,164 | $90 | - | - | - | $3,164 | |
04 | 2.6231: Utilize controls to operate equipment only when needed | $2,583 | $140 |
$2,583
46,447
kWh
|
- | - | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,702 | $1,018 |
$1,331
23,936
kWh
|
$371
-
kW-mo/yr
|
- | - | |
06 | 2.7447: Install vinyl strip / high speed / air curtain doors | $845 | $660 |
$845
15,257
kWh
|
- | - | - | |
07 | 2.7124: Make a practice of turning off lights when not needed | $405 | - |
$252
4,781
kWh
|
$153
-
kW-mo/yr
|
- | - | |
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $403 | $335 |
$403
6,021
kWh
|
- | - | - | |
09 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $290 | $24 |
$53
946
kWh
|
$12
-
kW-mo/yr
|
$225
-
gal
|
- | |
10 | 2.6218: Turn off equipment when not in use | $201 | - |
$105
1,916
kWh
|
$96
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $42,096 | $58,589 |
$27,147
482,431
kWh
|
$11,560
-
kW-mo/yr
|
$225
-
gal
|
$3,164 | ||
TOTAL IMPLEMENTED | $21,099 | $2,261 |
$15,714
281,581
kWh
|
$5,160
-
kW-mo/yr
|
$225
-
gal
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs