| Assessment Year | 2025 |
|---|---|
| Principal Product | Shelf Liner, Grip |
| NAICS | 322299: All Other Converted Paper Product Manufacturing |
| SIC | 2675: Die-Cut Paper and Paperboard and Cardboard |
| Sales Range | $10 M to 50M |
| # of Employees | 180 |
| Plant Area |
250,000
ft2
|
| Annual Production | 9,732,000
units
|
| Production Hrs. Annual | 4,160
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $156,158 | 1,344,056 |
kWh
|
$0.12 |
| Electricity Demand | $146,762 | 7,358 |
kW-mo/yr
|
$19.95 |
| Electricity Fees | $59,448 | - |
|
- |
| Natural Gas | $40,344 | 3,806 |
MMBtu
|
$10.60 |
| Other Gas | $10,145 | 1 |
MMBtu
|
$10,145.00 |
| TOTAL YEARLY COSTS | $412,857 | |||
| RECOMMENDED SAVINGS* | $613,294 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $360,332 | $3,128,595 |
$274,212
2,359,829
kWh
|
$86,120
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.3141: Use battery storage for demand control | $118,038 | $200,000 |
$118,038
1,015,820
kWh
|
- | - | - | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $75,467 | $293,581 |
$46,246
397,986
kWh
|
$23,721
-
kW-mo/yr
|
- | - | $5,500 | |
| 04 | 2.7134: Use photocell controls | $36,786 | $6,000 |
$15,181
130,647
kWh
|
$16,426
-
kW-mo/yr
|
- | $208 | $4,971 | |
| 05 | 2.2511: Insulate bare equipment | $13,658 | $2,310 | - | - |
$13,658
-
MMBtu
|
- | - | |
| 06 | 2.4322: Use or replace with energy efficient substitutes | $4,072 | $25,000 |
$4,072
35,041
kWh
|
- | - | - | - | |
| 07 | 2.2437: Recover waste heat from equipment | $3,694 | $5,000 | - | - |
$3,694
-
MMBtu
|
- | - | |
| 08 | 2.4133: Use most efficient type of electric motors | $1,247 | $910 |
$909
7,826
kWh
|
$338
-
kW-mo/yr
|
- | - | - | |
| TOTAL RECOMMENDED | $613,294 | $3,661,396 |
$458,658
3,947,149
kWh
|
$126,605
-
kW-mo/yr
|
$17,352
-
MMBtu
|
$208 | $10,471 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs