Assessment Year | 1992 |
---|---|
Principal Product | COSMETIC APPLICATORS |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 86 |
Plant Area |
n/a
|
Annual Production | 76,500,000
pieces
|
Production Hrs. Annual | 3,570
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $75,958 | 456,038 |
kWh
|
$0.17 |
Other Energy | $8,386 | 2,835 |
MMBtu
|
$2.96 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $74,767 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $36,483 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Other Energy Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $38,284 | - |
$40,754
244,725
kWh
|
$(-2,470.0)
-
MMBtu
|
- | |
02 | 2.8114: Change rate schedules or other changes in utility service | $35,797 | $1,500 |
$35,797
-
kWh
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $686 | $2 |
$713
4,396
kWh
|
- | $(-27.0) | |
TOTAL RECOMMENDED | $74,767 | $1,502 |
$77,264
249,121
kWh
|
$(-2,470.0)
-
MMBtu
|
$(-27.0) | ||
TOTAL IMPLEMENTED | $36,483 | $1,502 |
$36,510
4,396
kWh
|
- | $(-27.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs