| Assessment Year | 1999 |
|---|---|
| Principal Product | Tricot knit fabrics |
| NAICS |
n/a
|
| SIC | 2259: Knitting Mills, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 175 |
| Plant Area |
100,000
ft2
|
| Annual Production | 225,000
thousand feet
|
| Production Hrs. Annual | 7,200
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $246,944 | 8,822,099 |
kWh
|
$0.028 |
| Electricity Demand | $183,840 | 19,528 |
kW-mo/yr
|
$9.41 |
| Electricity Fees | $6,860 | - |
|
- |
| Natural Gas | $346,976 | 90,730 |
MMBtu
|
$3.82 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $108,959 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $100,694 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Water Consumption Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7111: Reduce illumination to minimum necessary levels | $434 | $120 |
$278
9,965
kWh
|
$156
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.4133: Use most efficient type of electric motors | $2,366 | $2,141 |
$1,516
54,220
kWh
|
$850
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.6218: Turn off equipment when not in use | $8,265 | $420 |
$5,292
189,039
kWh
|
$2,973
-
kW-mo/yr
|
- | - | - | |
| 04 | 3.5313: Increase amount of waste recovered for resale | $450 | $500 | - | - | - |
$450
-
lb
|
- | |
| 05 | 3.4115: Recover and reuse cooling water | $97,444 | $35,500 | - | - |
$37,020
-
MMBtu
|
- |
$60,424
-
Tgal
|
|
| TOTAL RECOMMENDED | $108,959 | $38,681 |
$7,086
253,224
kWh
|
$3,979
-
kW-mo/yr
|
$37,020
-
MMBtu
|
$450
-
lb
|
$60,424
-
Tgal
|
||
| TOTAL IMPLEMENTED | $100,694 | $38,261 |
$1,794
64,185
kWh
|
$1,006
-
kW-mo/yr
|
$37,020
-
MMBtu
|
$450
-
lb
|
$60,424
-
Tgal
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs