Assessment Year | 1998 |
---|---|
Principal Product | Finished Broadwoven Cotton Fabric |
NAICS |
n/a
|
SIC | 2261: Finishers of Broadwoven Fabrics of Cotton |
Sales Range | $10 M to 50M |
# of Employees | 70 |
Plant Area |
180,000
ft2
|
Annual Production | 3,750
thousand feet
|
Production Hrs. Annual | 2,860
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $107,403 | 2,203,986 |
kWh
|
$0.049 |
Electricity Demand | $88,948 | 11,331 |
kW-mo/yr
|
$7.85 |
Natural Gas | $199,780 | 59,758 |
MMBtu
|
$3.34 |
Fuel Oil #6 | $57,406 | 22,946 |
MMBtu
|
$2.50 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $56,500 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $246 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #6 Savings |
---|---|---|---|---|---|---|---|
01 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $16,605 | $14,585 |
$(-107.0)
(-2,052)
kWh
|
$(-71.0)
-
kW-mo/yr
|
$16,783
-
MMBtu
|
|
02 | 2.3413: Burn fossil fuel to produce steam to drive a steam turbine-generator and use steam exhaust for heat | $37,587 | $40,000 |
$23,080
440,504
kWh
|
$14,507
-
kW-mo/yr
|
- | |
03 | 2.7135: Install occupancy sensors | $2,062 | $6,430 |
$2,062
38,687
kWh
|
- | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $246 | $195 |
$246
4,689
kWh
|
- | - | |
TOTAL RECOMMENDED | $56,500 | $61,210 |
$25,281
481,828
kWh
|
$14,436
-
kW-mo/yr
|
$16,783
-
MMBtu
|
||
TOTAL IMPLEMENTED | $246 | $195 |
$246
4,689
kWh
|
- | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs