| Assessment Year | 1992 |
|---|---|
| Principal Product | HEAVY MACHINERY |
| NAICS |
n/a
|
| SIC | 3559: Special Industry Machinery, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 150 |
| Plant Area |
n/a
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 4,290
hrs
|
| Location (State) | Connecticut |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $226,535 | 2,235,053 |
kWh
|
$0.10 |
| Natural Gas | $77,754 | 14,889 |
MMBtu
|
$5.22 |
| Fuel Oil #6 | $53,544 | 15,034 |
MMBtu
|
$3.56 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $48,197 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $39,134 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Fuel Oil #2 Savings | Fuel Oil #6 Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $12,894 | $33 |
$12,894
127,198
kWh
|
- | - | - | - | |
| 02 | 2.6124: Establish equipment maintenance schedule | $11,199 | $1,500 | - |
$6,265
-
MMBtu
|
- |
$4,934
-
MMBtu
|
- | |
| 03 | 2.7226: Use computer programs to optimize hvac performance | $12,146 | $200 | - |
$6,795
-
MMBtu
|
- |
$5,351
-
MMBtu
|
- | |
| 04 | 2.7423: Reduce heat gain by window tinting | $5,744 | $5,800 | - | - |
$3,159
-
MMBtu
|
$2,585
-
MMBtu
|
- | |
| 05 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $3,319 | - |
$3,981
39,273
kWh
|
- | - |
$(-662.0)
-
MMBtu
|
- | |
| 06 | 2.7261: Install timers and/or thermostats | $980 | $4 |
$980
9,672
kWh
|
- | - | - | - | |
| 07 | 2.2113: Repair or replace steam traps | $785 | $1 | - |
$776
-
MMBtu
|
- |
$609
-
MMBtu
|
$(-600.0) | |
| 08 | 2.2122: Install / repair insulation on condensate lines | $365 | $220 | - |
$205
-
MMBtu
|
- |
$160
-
MMBtu
|
- | |
| 09 | 2.6232: Install set-back timers | $468 | $180 |
$468
4,689
kWh
|
- | - | - | - | |
| 10 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $297 | $400 |
$297
2,931
kWh
|
- | - | - | - | |
| TOTAL RECOMMENDED | $48,197 | $8,338 |
$18,620
183,763
kWh
|
$14,041
-
MMBtu
|
$3,159
-
MMBtu
|
$12,977
-
MMBtu
|
$(-600.0) | ||
| TOTAL IMPLEMENTED | $39,134 | $2,538 |
$14,639
144,490
kWh
|
$14,041
-
MMBtu
|
- |
$11,054
-
MMBtu
|
$(-600.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Fuel Oil #2 Savings | Fuel Oil #6 Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs