ITAC Assessment: MA0219
ITAC logo
ITAC Assessment: MA0219
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1991
Principal Product TEFLON TUBING
NAICS
n/a
SIC 3082: Unsupported Plastics Profile Shapes
Sales Range $5
M
to 10
M
# of Employees 160
Plant Area
n/a
Annual Production 300,000
lb
Production Hrs. Annual 6,240
hrs
Location (State) New Hampshire

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $276,343 3,738,570
kWh
LPG $4,303 428
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $84,615 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $84,615

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings LPG Savings
01 2.1311: Replace electrically-operated equipment with fossil fuel equipment $36,849 - $87,631
861,958
kWh
$(-50,782.0)
-
MMBtu
02 2.2426: Use waste heat from flue gases to heat space conditioning air $30,005 $7,000 $30,005
405,627
kWh
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $1,604 $446 $1,604
21,688
kWh
-
04 2.7261: Install timers and/or thermostats $6,693 $100 $1,994
26,964
kWh
$4,699
-
MMBtu
05 2.2711: Utilize outside air instead of conditioned air for drying $8,835 $3,850 $2,992
40,445
kWh
$5,843
-
MMBtu
06 2.6232: Install set-back timers $629 $85 $629
8,499
kWh
-
TOTAL RECOMMENDED $84,615 $11,481 $124,855
1,365,181
kWh
$(-40,240.0)
-
MMBtu
TOTAL IMPLEMENTED $84,615 $11,481 $124,855
1,365,181
kWh
$(-40,240.0)
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings LPG Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs