Assessment Year 1989
Principal Product MINIATURE BATTERIES
NAICS
n/a
SIC 3692: Primary Batteries, Dry and Wet
Sales Range $10
M
to 50
M
# of Employees 440
Plant Area
n/a
Annual Production 200,000
pieces
Production Hrs. Annual 5,880
hrs
Location (State) Vermont

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,037,878 14,443,142
kWh
Fuel Oil #2 $139,442 35,280
MMBtu
Fuel Oil #4 $76,399 24,912
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $121,308 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $94,112

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Fuel Oil #4 Savings
01 2.8114: Change rate schedules or other changes in utility service $93,444 $90,000 $93,444
-
kWh
-
02 2.7261: Install timers and/or thermostats $668 - - $668
-
MMBtu
03 2.7226: Use computer programs to optimize hvac performance $603 $1,500 $603
9,672
kWh
-
04 2.3413: Burn fossil fuel to produce steam to drive a steam turbine-generator and use steam exhaust for heat $25,296 $123,000 $38,870
577,374
kWh
$(-13,574.0)
-
MMBtu
05 2.6232: Install set-back timers $1,297 $323 $1,297
18,171
kWh
-
TOTAL RECOMMENDED $121,308 $214,823 $134,214
605,217
kWh
$(-12,906.0)
-
MMBtu
TOTAL IMPLEMENTED $94,112 $90,000 $93,444
-
kWh
$668
-
MMBtu
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs