Assessment Year | 1988 |
---|---|
Principal Product | CARBIDE INSERTS |
NAICS |
n/a
|
SIC | 3545: Cutting Tools, Machine Tool Accessories, and Machinists' Precision Measuring Devices |
Sales Range | $1 M to 5M |
# of Employees | 52 |
Plant Area |
n/a
|
Annual Production | 1,500,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $84,769 | 1,364,889 |
kWh
|
$0.062 |
Natural Gas | $379 | 95 |
MMBtu
|
$3.99 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $14,519 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $14,451 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.3191: Use demand controller or load shedder | $7,390 | $12,000 |
$7,390
-
kWh
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,550 | $1,000 |
$2,550
59,203
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,881 | $373 |
$1,881
35,756
kWh
|
|
04 | 2.6232: Install set-back timers | $1,280 | - |
$1,280
26,964
kWh
|
|
05 | 2.2511: Insulate bare equipment | $860 | $740 |
$860
19,930
kWh
|
|
06 | 2.4312: Improve lubrication practices | $370 | - |
$370
8,499
kWh
|
|
07 | 2.6127: Maintain air filters by cleaning or replacement | $68 | $150 |
$68
1,465
kWh
|
|
08 | 2.6212: Turn off equipment during breaks, reduce operating time | $120 | $100 |
$120
2,638
kWh
|
|
TOTAL RECOMMENDED | $14,519 | $14,363 |
$14,519
154,455
kWh
|
||
TOTAL IMPLEMENTED | $14,451 | $14,213 |
$14,451
152,990
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs