Assessment Year | 2001 |
---|---|
Principal Product | Metal burial vaults and steel coil processing |
NAICS |
n/a
|
SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 110 |
Plant Area |
250,000
ft2
|
Annual Production | 100,000
ton
|
Production Hrs. Annual | 3,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $183,550 | 3,769,222 |
kWh
|
$0.049 |
Electricity Demand | $36,978 | 10,032 |
kW-mo/yr
|
$3.69 |
Natural Gas | $346,322 | 54,927 |
MMBtu
|
$6.31 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $194,430 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,512 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 3.2176: Increase use of automation | $124,000 | $240,000 | - | - | - | - | - | $124,000 | - | |
02 | 2.2414: Use waste heat from hot flue gases to preheat | $26,445 | $5,700 | - | - |
$26,445
-
MMBtu
|
- | - | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,036 | $25,000 | - | - | - |
$4,812
-
gal
|
- | $4,224 | - | |
04 | 2.2136: Install / repair insulation on steam lines | $8,474 | $6,280 | - | - |
$8,474
-
MMBtu
|
- | - | - | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,038 | $1,450 |
$6,528
136,000
kWh
|
$1,510
-
kW-mo/yr
|
- | - | - | - | - | |
06 | 2.2414: Use waste heat from hot flue gases to preheat | $7,458 | $5,700 | - | - |
$7,458
-
MMBtu
|
- | - | - | - | |
07 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $4,522 | $3,000 | - | - | - | - |
$4,522
-
lb
|
- | - | |
08 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $3,394 | - |
$2,430
50,626
kWh
|
$964
-
kW-mo/yr
|
- | - | - | - | - | |
09 | 2.2421: Install waste heat boiler to provide direct power | $1,779 | $5,000 | - | - |
$1,779
-
MMBtu
|
- | - | - | - | |
10 | 3.4155: Meter waste water | $1,284 | $500 | - | - | - | - | - | - | $1,284 | |
TOTAL RECOMMENDED | $194,430 | $292,630 |
$8,958
186,626
kWh
|
$2,474
-
kW-mo/yr
|
$44,156
-
MMBtu
|
$4,812
-
gal
|
$4,522
-
lb
|
$128,224 | $1,284 | ||
TOTAL IMPLEMENTED | $16,512 | $7,730 |
$6,528
136,000
kWh
|
$1,510
-
kW-mo/yr
|
$8,474
-
MMBtu
|
- | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs