ITAC Assessment: MA0145
ITAC logo
ITAC Assessment: MA0145
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1989
Principal Product TANTALUM CAPACITORS
NAICS
n/a
SIC 3675: Electronic Capacitors
Sales Range $10
M
to 50
M
# of Employees 176
Plant Area
n/a
Annual Production 20,000,000
pieces
Production Hrs. Annual 4,460
hrs
Location (State) Maine

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $226,098 3,953,107
kWh
Fuel Oil #2 $15,378 3,910
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $11,454 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,807

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Fuel Oil #2 Savings
01 2.6218: Turn off equipment when not in use $3,559 - $3,264
80,598
kWh
$295
-
MMBtu
02 2.1311: Replace electrically-operated equipment with fossil fuel equipment $3,230 $4,500 $5,380
94,080
kWh
$(-2,150.0)
-
MMBtu
03 2.2437: Recover waste heat from equipment $2,036 $4,870 - $2,036
-
MMBtu
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,228 $160 $1,228
21,395
kWh
-
05 2.4221: Install compressor air intakes in coolest locations $824 $356 $824
14,361
kWh
-
06 2.6218: Turn off equipment when not in use $246 $87 $246
6,155
kWh
-
07 2.6232: Install set-back timers $206 $525 $206
4,982
kWh
-
08 2.4111: Utilize energy-efficient belts and other improved mechanisms $125 - $125
2,345
kWh
-
TOTAL RECOMMENDED $11,454 $10,498 $11,273
223,916
kWh
$181
-
MMBtu
TOTAL IMPLEMENTED $3,807 $5,112 $5,957
107,562
kWh
$(-2,150.0)
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Fuel Oil #2 Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs