Assessment Year | 2007 |
---|---|
Principal Product | Calendered PVC Films and Laminates |
NAICS | 323111: Commercial Printing (except Screen and Books) |
SIC | 2754: Commercial Printing, Gravure |
Sales Range | $10 M to 50M |
# of Employees | 95 |
Plant Area |
100,000
ft2
|
Annual Production | 14,000,000
lb
|
Production Hrs. Annual | 4,800
hrs
|
Location (State) | Maryland |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,425,532 | 14,085,691 |
kWh
|
$0.10 |
Natural Gas | $518,500 | 28,806 |
MMBtu
|
$18.00 |
Fuel Oil #6 | $537,191 | 66,936 |
MMBtu
|
$8.03 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $111,195 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Fuel Oil #6 Savings |
---|---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $21,414 | $10,000 | - | - |
$21,414
-
MMBtu
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $49,771 | $62,783 |
$49,771
469,971
kWh
|
- | - | |
03 | 2.2622: Replace existing chiller with high efficiency model | $19,418 | $73,950 |
$19,418
183,362
kWh
|
- | - | |
04 | 2.9111: Use solar heat to heat make-up air | $20,592 | $100,100 | - |
$20,592
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $111,195 | $246,833 |
$69,189
653,333
kWh
|
$20,592
-
MMBtu
|
$21,414
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - |