Assessment Year | 1988 |
---|---|
Principal Product | COSMETIC MIRRORS |
NAICS |
n/a
|
SIC | 3231: Glass Products, Made of Purchased Glass |
Sales Range | $5 M to 10M |
# of Employees | 205 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,860
hrs
|
Location (State) | Connecticut |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $114,962 | 1,505,862 |
kWh
|
$0.076 |
Natural Gas | $52,348 | 9,602 |
MMBtu
|
$5.45 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $23,119 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $22,330 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $201 | $150 |
$201
2,638
kWh
|
- | - | |
02 | 2.7261: Install timers and/or thermostats | $13,920 | $448 |
$3,669
48,066
kWh
|
$10,251
-
MMBtu
|
- | |
03 | 2.7226: Use computer programs to optimize hvac performance | $671 | $6,000 |
$671
8,792
kWh
|
- | - | |
04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $229 | $100 | - |
$349
-
MMBtu
|
$(-120.0) | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,901 | $458 |
$1,901
24,912
kWh
|
- | - | |
06 | 2.6232: Install set-back timers | $118 | $354 |
$118
1,465
kWh
|
- | - | |
07 | 2.7224: Reduce space conditioning during non-working hours | $1,812 | $520 |
$1,812
23,740
kWh
|
- | - | |
08 | 2.1221: Replace obsolete burners with more efficient ones | $1,461 | $3,000 | - |
$1,461
-
MMBtu
|
- | |
09 | 2.1221: Replace obsolete burners with more efficient ones | $2,806 | $10,500 | - |
$2,806
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $23,119 | $21,530 |
$8,372
109,613
kWh
|
$14,867
-
MMBtu
|
$(-120.0) | ||
TOTAL IMPLEMENTED | $22,330 | $15,176 |
$7,583
99,356
kWh
|
$14,867
-
MMBtu
|
$(-120.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs