Assessment Year | 2002 |
---|---|
Principal Product | compressed air tools |
NAICS |
n/a
|
SIC | 3546: Power-Driven Handtools |
Sales Range | $5 M to 10M |
# of Employees | 40 |
Plant Area |
30,000
ft2
|
Annual Production | 41,850
pieces
|
Production Hrs. Annual | 5,749
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $18,641 | 690,411 |
kWh
|
$0.027 |
Electricity Demand | $26,918 | 3,786 |
kW-mo/yr
|
$7.11 |
LPG | $6,415 | 412 |
MMBtu
|
$15.57 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $3,310 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,700 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,330 | $300 |
$1,330
49,200
kWh
|
- | - | |
02 | 3.7198: Reduce / eliminate use of disposable product | $920 | $699 | - | - |
$920
-
lb
|
|
03 | 2.7111: Reduce illumination to minimum necessary levels | $690 | $210 |
$290
10,600
kWh
|
$400
-
kW-mo/yr
|
- | |
04 | 2.7124: Make a practice of turning off lights when not needed | $190 | - |
$120
4,340
kWh
|
$70
-
kW-mo/yr
|
- | |
05 | 3.7132: Reuse rags until completely soiled | $180 | - | - | - |
$180
-
lb
|
|
TOTAL RECOMMENDED | $3,310 | $1,209 |
$1,740
64,140
kWh
|
$470
-
kW-mo/yr
|
$1,100
-
lb
|
||
TOTAL IMPLEMENTED | $1,700 | $300 |
$1,450
53,540
kWh
|
$70
-
kW-mo/yr
|
$180
-
lb
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs