Assessment Year | 1988 |
---|---|
Principal Product | ELECTRICAL COMPONENTS |
NAICS |
n/a
|
SIC | 3629: Electrical Industrial Apparatus, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
n/a
|
Annual Production | 7,250,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Vermont |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $328,552 | 4,599,062 |
kWh
|
$0.071 |
LPG | $9,458 | 1,055 |
MMBtu
|
$8.96 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $102,289 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings |
---|---|---|---|---|---|---|
01 | 2.6212: Turn off equipment during breaks, reduce operating time | $3,682 | $70 |
$3,682
67,116
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $870 | $542 |
$870
12,016
kWh
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $962 | $231 |
$962
12,309
kWh
|
- | |
04 | 2.7226: Use computer programs to optimize hvac performance | $25,643 | $42,500 |
$25,643
604,631
kWh
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,063 | $9,516 |
$10,063
140,387
kWh
|
- | |
06 | 2.7261: Install timers and/or thermostats | $2,845 | $1,275 |
$2,845
74,443
kWh
|
- | |
07 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $36,657 | $46,930 |
$74,279
1,046,014
kWh
|
$(-37,622.0)
-
MMBtu
|
|
09 | 2.3191: Use demand controller or load shedder | $2,073 | $295 |
$2,073
-
kWh
|
- | |
10 | 2.7226: Use computer programs to optimize hvac performance | $3,650 | $6,000 |
$3,650
-
kWh
|
- | |
11 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $15,844 | - |
$26,101
142,732
kWh
|
$(-10,257.0)
-
MMBtu
|
|
TOTAL RECOMMENDED | $102,289 | $107,359 |
$150,168
2,099,648
kWh
|
$(-47,879.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | LPG Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs