Assessment Year | 1987 |
---|---|
Principal Product | ENVELOPES |
NAICS |
n/a
|
SIC | 2677: Envelopes |
Sales Range | $10 M to 50M |
# of Employees | 500 |
Plant Area |
n/a
|
Annual Production | 30,000,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $394,455 | 5,330,012 |
kWh
|
$0.074 |
Natural Gas | $5,265 | 689 |
MMBtu
|
$7.64 |
Fuel Oil #2 | $25,188 | 5,880 |
MMBtu
|
$4.28 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $15,617 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,444 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,938 | $785 |
$4,938
66,530
kWh
|
- | - | |
02 | 2.6232: Install set-back timers | $3,744 | $450 |
$3,744
50,703
kWh
|
- | - | |
03 | 2.4221: Install compressor air intakes in coolest locations | $916 | $250 |
$916
12,309
kWh
|
- | - | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,650 | - |
$3,650
49,238
kWh
|
- | - | |
05 | 2.4321: Upgrade obsolete equipment | $1,429 | $4,000 |
$1,429
19,343
kWh
|
- | - | |
06 | 2.2113: Repair or replace steam traps | $940 | $900 | - |
$1,840
-
MMBtu
|
$(-900.0) | |
TOTAL RECOMMENDED | $15,617 | $6,385 |
$14,677
198,123
kWh
|
$1,840
-
MMBtu
|
$(-900.0) | ||
TOTAL IMPLEMENTED | $10,444 | $1,935 |
$9,504
128,077
kWh
|
$1,840
-
MMBtu
|
$(-900.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Fuel Oil #2 Savings | Administrative Changes Savings |