Assessment Year | 1987 |
---|---|
Principal Product | ELECTRONIC COMPONENTS |
NAICS |
n/a
|
SIC | 3825: Instruments for Measuring and Testing of Electricity and Electrical Signals |
Sales Range | $10 M to 50M |
# of Employees | 300 |
Plant Area |
n/a
|
Annual Production | 1,365
pieces
|
Production Hrs. Annual | 2,500
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $234,990 | 2,490,621 |
kWh
|
$0.094 |
Natural Gas | $22,588 | 3,403 |
MMBtu
|
$6.64 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $30,282 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,745 | $901 |
$2,745
29,015
kWh
|
- | |
02 | 2.6212: Turn off equipment during breaks, reduce operating time | $2,660 | $43 |
$190
2,052
kWh
|
$2,470
-
MMBtu
|
|
03 | 2.6212: Turn off equipment during breaks, reduce operating time | $943 | - |
$943
9,965
kWh
|
- | |
04 | 2.7261: Install timers and/or thermostats | $9,216 | $935 | - |
$9,216
-
MMBtu
|
|
05 | 2.6124: Establish equipment maintenance schedule | $14,656 | $3,520 |
$14,656
155,334
kWh
|
- | |
06 | 2.4221: Install compressor air intakes in coolest locations | $62 | $200 |
$62
586
kWh
|
- | |
TOTAL RECOMMENDED | $30,282 | $5,599 |
$18,596
196,952
kWh
|
$11,686
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs