| Assessment Year | 1988 |
|---|---|
| Principal Product | CONVERTED PAPER |
| NAICS |
n/a
|
| SIC | 2679: Converted Paper and Paperboard Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 88 |
| Plant Area |
n/a
|
| Annual Production | 68,000
ton
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $231,768 | 4,427,902 |
kWh
|
$0.052 |
| Natural Gas | $5,796 | 3,057 |
MMBtu
|
$1.90 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $11,127 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $9,541 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7231: Use radiant heater for spot heating | $340 | $5,000 | - |
$340
-
MMBtu
|
- | |
| 02 | 2.7229: Air condition only space necessary | $2,754 | - |
$1,466
35,756
kWh
|
$1,288
-
MMBtu
|
- | |
| 03 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $345 | - |
$345
8,499
kWh
|
- | - | |
| 04 | 2.6232: Install set-back timers | $3,315 | - |
$3,315
80,891
kWh
|
- | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $183 | $118 |
$208
4,103
kWh
|
- | $(-25.0) | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,177 | $475 |
$992
21,981
kWh
|
- | $185 | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $716 | $315 |
$980
24,033
kWh
|
- | $(-264.0) | |
| 08 | 2.6212: Turn off equipment during breaks, reduce operating time | $365 | - |
$365
8,792
kWh
|
- | - | |
| 09 | 2.4133: Use most efficient type of electric motors | $564 | $890 |
$564
12,309
kWh
|
- | - | |
| 10 | 2.7261: Install timers and/or thermostats | $185 | $69 |
$85
13,189
kWh
|
$100
-
MMBtu
|
- | |
| 11 | 2.7224: Reduce space conditioning during non-working hours | $313 | $50 |
$313
7,620
kWh
|
- | - | |
| 12 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $870 | $2,000 |
$992
17,878
kWh
|
$(-122.0)
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $11,127 | $8,917 |
$9,625
235,051
kWh
|
$1,606
-
MMBtu
|
$(-104.0) | ||
| TOTAL IMPLEMENTED | $9,541 | $6,602 |
$7,653
193,140
kWh
|
$1,728
-
MMBtu
|
$160 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs