| Assessment Year | 1986 |
|---|---|
| Principal Product | ALUMINUM INGOTS |
| NAICS |
n/a
|
| SIC | 3399: Primary Metal Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 110 |
| Plant Area |
n/a
|
| Annual Production | 84,000,000
lb
|
| Production Hrs. Annual | 8,520
hrs
|
| Location (State) | Arkansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $240,461 | 4,550,117 |
kWh
|
$0.053 |
| Natural Gas | $1,113,005 | 298,841 |
MMBtu
|
$3.72 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $146,812 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $3,435 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2414: Use waste heat from hot flue gases to preheat | $138,229 | $20,020 |
$(-1,405.0)
(-35,170)
kWh
|
$139,634
-
MMBtu
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $115 | $58 |
$115
1,465
kWh
|
- | |
| 03 | 2.6232: Install set-back timers | $2,358 | - |
$2,358
42,497
kWh
|
- | |
| 04 | 2.7261: Install timers and/or thermostats | $962 | $450 |
$787
32,825
kWh
|
$175
-
MMBtu
|
|
| 05 | 2.2514: Cover open tanks | $5,148 | $2,840 | - |
$5,148
-
MMBtu
|
|
| TOTAL RECOMMENDED | $146,812 | $23,368 |
$1,855
41,617
kWh
|
$144,957
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $3,435 | $508 |
$3,260
76,787
kWh
|
$175
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs