Assessment Year 1985
Principal Product POLYETHYLENE FILM PRODUCTS
NAICS
n/a
SIC 3083: Laminated Plastics Plate, Sheet, and Profile Shapes
Sales Range $10
M
to 50
M
# of Employees 112
Plant Area
n/a
Annual Production 45,000,000
lb
Production Hrs. Annual 8,686
hrs
Location (State) Louisiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $629,652 13,282,826
kWh
Natural Gas $40,620 8,646
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $27,011 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $10,788

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7111: Reduce illumination to minimum necessary levels $1,544 - $1,544
37,515
kWh
-
02 2.7121: Utilize daylight whenever possible in lieu of artificial light $3,879 $8,181 $3,879
100,821
kWh
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $3,161 $680 $3,161
74,736
kWh
-
04 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,403 $139 $1,403
33,411
kWh
-
05 2.7261: Install timers and/or thermostats $1,121 $450 $725
18,757
kWh
$396
-
MMBtu
06 2.7261: Install timers and/or thermostats $2,627 $60 - $2,627
-
MMBtu
07 2.2511: Insulate bare equipment $5,430 $1,840 $5,430
140,973
kWh
-
08 2.2515: Use optimum thickness insulation $7,330 $750 $7,330
190,211
kWh
-
09 2.4221: Install compressor air intakes in coolest locations $516 $100 $516
13,482
kWh
-
TOTAL RECOMMENDED $27,011 $12,200 $23,988
609,906
kWh
$3,023
-
MMBtu
TOTAL IMPLEMENTED $10,788 $9,371 $7,765
194,314
kWh
$3,023
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs