Assessment Year | 1985 |
---|---|
Principal Product | DRAPERIES |
NAICS |
n/a
|
SIC | 2391: Curtains and Draperies |
Sales Range | $500 k to 1M |
# of Employees | 25 |
Plant Area |
n/a
|
Annual Production | 276
thousand feet
|
Production Hrs. Annual | 2,125
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $8,357 | 119,871 |
kWh
|
$0.070 |
Natural Gas | $2,547 | 524 |
MMBtu
|
$4.86 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $3,630 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,901 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7261: Install timers and/or thermostats | $2,397 | $59 |
$190
2,638
kWh
|
$2,207
-
MMBtu
|
|
02 | 2.7492: Use proper thickness of insulation on building envelope | $46 | $75 | - |
$46
-
MMBtu
|
|
03 | 2.7492: Use proper thickness of insulation on building envelope | $456 | $237 |
$55
879
kWh
|
$401
-
MMBtu
|
|
04 | 2.7441: Replace broken windows and/or window sash | $458 | $81 |
$55
879
kWh
|
$403
-
MMBtu
|
|
05 | 2.7111: Reduce illumination to minimum necessary levels | $273 | $60 |
$273
4,103
kWh
|
- | |
TOTAL RECOMMENDED | $3,630 | $512 |
$573
8,499
kWh
|
$3,057
-
MMBtu
|
||
TOTAL IMPLEMENTED | $2,901 | $215 |
$245
3,517
kWh
|
$2,656
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs