Assessment Year | 1984 |
---|---|
Principal Product | PAPER PACKAGING MACHINES |
NAICS |
n/a
|
SIC | 3554: Paper Industries Machinery |
Sales Range | $5 M to 10M |
# of Employees | 101 |
Plant Area |
n/a
|
Annual Production | 27
pieces
|
Production Hrs. Annual | 2,320
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $34,853 | 587,046 |
kWh
|
$0.059 |
Natural Gas | $24,435 | 3,834 |
MMBtu
|
$6.37 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,076 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,720 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2511: Insulate bare equipment | $157 | $200 |
$157
2,638
kWh
|
- | |
02 | 2.2514: Cover open tanks | $174 | $48 |
$174
2,931
kWh
|
- | |
03 | 2.2532: Use only amount of air necessary to prevent explosion hazard | $605 | $74 | - |
$605
-
MMBtu
|
|
04 | 2.7261: Install timers and/or thermostats | $2,412 | - |
$1,132
19,050
kWh
|
$1,280
-
MMBtu
|
|
05 | 2.4221: Install compressor air intakes in coolest locations | $522 | $400 |
$522
8,792
kWh
|
- | |
06 | 2.1321: Replace fossil fuel equipment with electrical equipment | $751 | $1,434 |
$(-453.0)
(-7,620)
kWh
|
$1,204
-
MMBtu
|
|
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,229 | $573 |
$2,229
37,515
kWh
|
- | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $226 | $321 |
$226
3,810
kWh
|
- | |
TOTAL RECOMMENDED | $7,076 | $3,050 |
$3,987
67,116
kWh
|
$3,089
-
MMBtu
|
||
TOTAL IMPLEMENTED | $5,720 | $1,542 |
$4,440
74,736
kWh
|
$1,280
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs