Assessment Year | 2025 |
---|---|
Principal Product | Fabricated Pipe and Fittings |
NAICS | 332996: Fabricated Pipe and Pipe Fitting Manufacturing |
SIC | 3498: Fabricated Pipe and Pipe Fittings |
Sales Range | $50 M to 100M |
# of Employees | 140 |
Plant Area |
92,452
ft2
|
Annual Production | 10,500,000
lb
|
Production Hrs. Annual | 4,394
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $164,420 | 1,409,856 |
kWh
|
$0.12 | |
Electricity Demand | $6,789 | 1,942 |
kW-mo/yr
|
$3.50 | |
Natural Gas | $266,172 | 27,643 |
MMBtu
|
$9.63 | |
LPG | $45,301 | 408 |
MMBtu
|
$111.03 | |
Waste Disposal Costs | |||||
Solid Waste (non-haz) | $103,510 | 173,500 |
lb
|
$0.60 | |
TOTAL YEARLY COSTS | $586,192 | ||||
RECOMMENDED SAVINGS* | $380,860 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 3.5316: Contract a wood pallet recycling company | $3,510 | - | - | - |
$3,510
-
lb
|
- | - | |
02 | 2.7226: Use computer programs to optimize hvac performance | $3,440 | $35 |
$3,440
29,400
kWh
|
- | - | - | - | |
03 | 2.7135: Install occupancy sensors | $9,938 | $200 |
$9,938
84,944
kWh
|
- | - | - | - | |
04 | 2.7211: Clean and maintain refrigerant condensers and towers | $1,184 | $241 |
$1,184
10,121
kWh
|
- | - | - | - | |
05 | 3.5217: Reuse / recycle/ sell paper products | $104,805 | $23,000 |
$(-945.0)
(-8,081)
kWh
|
- |
$100,000
-
lb
|
- | $5,750 | |
06 | 2.1321: Replace fossil fuel equipment with electrical equipment | $83,111 | $240,915 |
$(-2,190.0)
(-18,720)
kWh
|
$45,301
-
MMBtu
|
- | $40,000 | - | |
07 | 4.322: Eliminate old stock and modify inventory control | $6,500 | $20,000 | - | - | - | $6,500 | - | |
08 | 4.652: Replace existing equipment with more suitable substitutes | $113,606 | $398,500 |
$7,631
65,221
kWh
|
- | - | $105,975 | - | |
09 | 2.4226: Use / purchase optimum sized compressor | $5,467 | $37,172 |
$5,467
46,723
kWh
|
- | - | - | - | |
10 | 2.9114: Use solar heat to make electricty | $49,299 | $483,600 |
$49,299
421,360
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $380,860 | $1,203,663 |
$73,824
630,968
kWh
|
$45,301
-
MMBtu
|
$103,510
-
lb
|
$152,475 | $5,750 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | LPG Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs