ITAC Assessment: LS2208
ITAC logo
ITAC Assessment: LS2208
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2022
Principal Product Oil Field Tools
NAICS 333132: Oil and Gas Field Machinery and Equipment Manufacturing
SIC 3533: Oil and Gas Field Machinery and Equipment
Sales Range less than $500
k
# of Employees 80
Plant Area 342,511
ft2
Annual Production 1
units
Production Hrs. Annual 4,004
hrs
Location (State) Louisiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $145,642 1,395,660
kWh
Fuel Oil #2 $46,715 1,945
MMBtu
TOTAL YEARLY COSTS $192,357
RECOMMENDED SAVINGS* $50,436 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $23,256

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Fuel Oil #2 Savings
01 2.2694: Use highest temperature for chilling or cold storage $378 $10 $378
3,626
kWh
-
02 2.7261: Install timers and/or thermostats $7,289 $200 $7,289
69,845
kWh
-
03 2.4231: Reduce the pressure of compressed air to the minimum required $651 $50 $651
6,235
kWh
-
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $5,527 $450 $5,527
52,968
kWh
-
05 2.7447: Install vinyl strip / high speed / air curtain doors $975 $240 $975
9,340
kWh
-
06 2.2414: Use waste heat from hot flue gases to preheat $9,660 $2,800 - $9,660
-
MMBtu
07 2.7135: Install occupancy sensors $304 $114 $304
2,915
kWh
-
08 2.7142: Utilize higher efficiency lamps and/or ballasts $10,440 $14,643 $10,440
100,048
kWh
-
09 2.9114: Use solar heat to make electricty $15,212 $215,340 $15,212
145,769
kWh
-
TOTAL RECOMMENDED $50,436 $233,847 $40,776
390,746
kWh
$9,660
-
MMBtu
TOTAL IMPLEMENTED $23,256 $15,293 $23,256
222,861
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Fuel Oil #2 Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs