Assessment Year 2022
Principal Product Refrigerated Warehousing and Storage
NAICS 493120: Refrigerated Warehousing and Storage
SIC 4222: Refrigerated Warehousing and Storage
Sales Range less than $500
k
# of Employees 50
Plant Area 175,000
ft2
Annual Production 1
units
Production Hrs. Annual 2,210
hrs
Location (State) Louisiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $89,098 1,142,204
kWh
Electricity Demand $13,756 3,349
kW-mo/yr
Fuel Oil #2 $66,410 1,875
MMBtu
TOTAL YEARLY COSTS $169,264
RECOMMENDED SAVINGS* $28,374 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $2,393

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings
01 2.7124: Make a practice of turning off lights when not needed $205 - $205
2,626
kWh
- -
02 2.8113: Purchase gas directly from a contract gas supplier $25,938 - - - $25,938
03 2.7261: Install timers and/or thermostats $430 $38 $430
5,507
kWh
- -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $659 $135 $659
8,445
kWh
- -
05 2.7134: Use photocell controls $722 $333 $722
9,261
kWh
- -
06 2.4231: Reduce the pressure of compressed air to the minimum required $43 $25 $43
550
kWh
- -
07 2.7447: Install vinyl strip / high speed / air curtain doors $233 $200 $233
2,988
kWh
- -
08 2.7444: Close holes and openings in building such as broken windows $20 $35 $20
250
kWh
- -
09 2.7142: Utilize higher efficiency lamps and/or ballasts $124 $360 $96
1,238
kWh
$28
-
kW-mo/yr
-
TOTAL RECOMMENDED $28,374 $1,126 $2,408
30,865
kWh
$28
-
kW-mo/yr
$25,938
TOTAL IMPLEMENTED $2,393 $1,101 $2,365
30,315
kWh
$28
-
kW-mo/yr
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs