Assessment Year 2022
Principal Product Retail
NAICS 451110: Sporting Goods Stores
SIC 5941: Sporting Goods Stores and Bicycle Shops
Sales Range less than $500
k
# of Employees 100
Plant Area 165,000
ft2
Annual Production 1
units
Production Hrs. Annual 3,900
hrs
Location (State) Louisiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $240,720 2,929,822
kWh
Electricity Demand $30,504 7,404
kW-mo/yr
Natural Gas $12,748 1,590
MMBtu
Waste Disposal Costs
Water Usage $10,684 6,727
Tgal
TOTAL YEARLY COSTS $294,656
RECOMMENDED SAVINGS* $29,049 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $28,024

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.7261: Install timers and/or thermostats $7,800 - $7,800
94,933
kWh
-
02 2.7134: Use photocell controls $1,326 $74 $1,326
16,144
kWh
-
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,012 $135 $1,012
12,310
kWh
-
04 2.7135: Install occupancy sensors $496 $250 $496
6,040
kWh
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $18,312 $11,682 $15,864
193,081
kWh
$2,448
-
kW-mo/yr
06 2.7447: Install vinyl strip / high speed / air curtain doors $90 $165 $90
1,098
kWh
-
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $13 $38 $13
156
kWh
-
TOTAL RECOMMENDED $29,049 $12,344 $26,601
323,762
kWh
$2,448
-
kW-mo/yr
TOTAL IMPLEMENTED $28,024 $12,171 $25,576
311,296
kWh
$2,448
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs