| Assessment Year | 2017 |
|---|---|
| Principal Product | Portable Drinking Water |
| NAICS | 221310: Water Supply and Irrigation Systems |
| SIC | 4941: Water Supply |
| Sales Range | $10 M to 50M |
| # of Employees | 265 |
| Plant Area |
36,020
ft2
|
| Annual Production | 2,424,366
units
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $290,800 | 4,409,600 |
kWh
|
$0.066 |
| Electricity Demand | $39,815 | 9,664 |
kW-mo/yr
|
$4.12 |
| Natural Gas | $1,085 | 130 |
MMBtu
|
$8.35 |
| TOTAL YEARLY COSTS | $331,700 | |||
| RECOMMENDED SAVINGS* | $35,627 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $291 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4131: Size electric motors for peak operating efficiency | $30,575 | $67,000 |
$14,912
226,115
kWh
|
$15,663
-
kW-mo/yr
|
|
| 02 | 2.7261: Install timers and/or thermostats | $1,608 | $600 |
$1,608
24,399
kWh
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,983 | $9,913 |
$2,259
34,528
kWh
|
$724
-
kW-mo/yr
|
|
| 04 | 2.7135: Install occupancy sensors | $170 | $210 |
$170
2,582
kWh
|
- | |
| 05 | 2.7442: Keep doors and windows shut when not on use | $291 | - |
$291
4,416
kWh
|
- | |
| TOTAL RECOMMENDED | $35,627 | $77,723 |
$19,240
292,040
kWh
|
$16,387
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $291 | - |
$291
4,416
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs