Assessment Year | 2003 |
---|---|
Principal Product | pharmaceutical products |
NAICS | 325414: Biological Product (except Diagnostic) Manufacturing |
SIC | 2836: Biological Products, Except Diagnostic Substances |
Sales Range | $100 M to 500M |
# of Employees | 240 |
Plant Area |
134,000
ft2
|
Annual Production | 2,400,000
pieces
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,477,174 | 68,956,970 |
kWh
|
$0.021 |
Electricity Demand | $331,384 | 24,384 |
kW-mo/yr
|
$13.59 |
Electricity Fees | $8,324 | - |
|
- |
Natural Gas | $322,154 | 54,232 |
MMBtu
|
$5.94 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $616,603 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $288,127 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Water Consumption Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $232 | $20 |
$196
1,848
kWh
|
$36
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.4221: Install compressor air intakes in coolest locations | $3,316 | $1,380 |
$2,813
26,489
kWh
|
$503
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,794 | $516 |
$4,447
41,720
kWh
|
$347
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.4133: Use most efficient type of electric motors | $1,296 | $792 |
$1,066
10,036
kWh
|
$230
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.7144: Install spectral reflectors / delamp | $13,658 | $360 |
$10,240
94,128
kWh
|
$3,418
-
kW-mo/yr
|
- | - | - | - | |
06 | 2.7124: Make a practice of turning off lights when not needed | $5,314 | - |
$4,239
35,653
kWh
|
$1,075
-
kW-mo/yr
|
- | - | - | - | |
07 | 2.7135: Install occupancy sensors | $2,760 | $521 |
$2,029
19,078
kWh
|
$731
-
kW-mo/yr
|
- | - | - | - | |
08 | 2.2414: Use waste heat from hot flue gases to preheat | $5,802 | $17,200 | - | - |
$5,802
-
MMBtu
|
- | - | - | |
09 | 2.7261: Install timers and/or thermostats | $17,717 | $120 |
$17,717
199,400
kWh
|
- | - | - | - | - | |
10 | 3.4115: Recover and reuse cooling water | $40,647 | $5,000 |
$27,657
260,400
kWh
|
$7,146
-
kW-mo/yr
|
- | - |
$5,844
-
Tgal
|
- | |
11 | 4.422: Utilize outside contracting | $56,838 | $11,800 | - | - | - | $56,838 | - | - | |
12 | 4.422: Utilize outside contracting | $234,229 | $100,000 | - | - | - | $234,229 | - | - | |
13 | 4.711: Initiate a total quality management program | $230,000 | $336,269 | - | - | - | - | - | $230,000 | |
TOTAL RECOMMENDED | $616,603 | $473,978 |
$70,404
688,752
kWh
|
$13,486
-
kW-mo/yr
|
$5,802
-
MMBtu
|
$291,067 |
$5,844
-
Tgal
|
$230,000 | ||
TOTAL IMPLEMENTED | $288,127 | $344,478 |
$42,251
393,376
kWh
|
$10,032
-
kW-mo/yr
|
- | - |
$5,844
-
Tgal
|
$230,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Water Consumption Savings | Increase in Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs