| Assessment Year | 2010 |
|---|---|
| Principal Product | Tube Alloy |
| NAICS | 332811: Metal Heat Treating |
| SIC | 3498: Fabricated Pipe and Pipe Fittings |
| Sales Range | $10 M to 50M |
| # of Employees | 100 |
| Plant Area |
15,000
ft2
|
| Annual Production | 4,000,000
pieces
|
| Production Hrs. Annual | 3,120
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $277,361 | 3,603,365 |
kWh
|
$0.077 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $44,652 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $42,724 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4222: Install adequate dryers on air lines to eliminate blowdown | $26,498 | $304 |
$26,498
344,263
kWh
|
- | |
| 02 | 2.7224: Reduce space conditioning during non-working hours | $9,654 | $3,600 |
$9,654
125,424
kWh
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,572 | $2,800 |
$6,572
85,389
kWh
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,119 | $700 |
$512
6,658
kWh
|
$607 | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $406 | $1,435 |
$406
5,271
kWh
|
- | |
| 06 | 2.6211: Conserve energy by efficient use of vending machines | $403 | $471 |
$403
5,242
kWh
|
- | |
| TOTAL RECOMMENDED | $44,652 | $9,310 |
$44,045
572,247
kWh
|
$607 | ||
| TOTAL IMPLEMENTED | $42,724 | $6,704 |
$42,724
555,076
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs