Assessment Year | 2005 |
---|---|
Principal Product | Oilfield equipment--offshore platforms |
NAICS | 333132: Oil and Gas Field Machinery and Equipment Manufacturing |
SIC | 3533: Oil and Gas Field Machinery and Equipment |
Sales Range | $100 M to 500M |
# of Employees | 150 |
Plant Area |
1,400,000
ft2
|
Annual Production | 20,000
ton
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,371,982 | 19,277,435 |
kWh
|
$0.071 |
Electricity Demand | $295,740 | 79,235 |
kW-mo/yr
|
$3.73 |
Electricity Fees | $82,268 | - |
|
- |
Natural Gas | $97,564 | 12,659 |
MMBtu
|
$7.71 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $145,352 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $144,931 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7111: Reduce illumination to minimum necessary levels | $40,093 | $2,862 |
$35,199
494,583
kWh
|
$3,021
-
kW-mo/yr
|
$1,873 | - | - | - | |
02 | 2.7134: Use photocell controls | $28,394 | $1,110 |
$27,068
380,323
kWh
|
- | $1,326 | - | - | - | |
03 | 2.4226: Use / purchase optimum sized compressor | $24,138 | $143,240 |
$19,989
280,861
kWh
|
$3,021
-
kW-mo/yr
|
$1,128 | - | - | - | |
04 | 2.7261: Install timers and/or thermostats | $15,054 | $726 | - | - | - |
$15,054
-
MMBtu
|
- | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $11,827 | $12,200 |
$11,275
158,418
kWh
|
- | $552 | - | - | - | |
06 | 2.7135: Install occupancy sensors | $2,004 | $990 |
$1,910
26,834
kWh
|
- | $94 | - | - | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,657 | $1,050 |
$711
9,986
kWh
|
- | $35 | - | $911 | - | |
08 | 2.7224: Reduce space conditioning during non-working hours | $421 | $770 |
$401
5,633
kWh
|
- | $20 | - | - | - | |
09 | 4.611: Begin a practice of predictive / preventative maintenance | $21,764 | $230 |
$252
3,536
kWh
|
- | $12 | - | $20,000 | $1,500 | |
TOTAL RECOMMENDED | $145,352 | $163,178 |
$96,805
1,360,174
kWh
|
$6,042
-
kW-mo/yr
|
$5,040 |
$15,054
-
MMBtu
|
$20,911 | $1,500 | ||
TOTAL IMPLEMENTED | $144,931 | $162,408 |
$96,404
1,354,541
kWh
|
$6,042
-
kW-mo/yr
|
$5,020 |
$15,054
-
MMBtu
|
$20,911 | $1,500 | ||