| Assessment Year | 2026 |
|---|---|
| Principal Product | aerosols |
| NAICS | 332439: Other Metal Container Manufacturing |
| SIC | 2844: Perfumes, Cosmetics, and Other Toilet Preparations |
| Sales Range | $50 M to 100M |
| # of Employees | 68 |
| Plant Area |
45,000
ft2
|
| Annual Production | 42,000,000
units
|
| Production Hrs. Annual | 4,420
hrs
|
| Location (State) | New Jersey |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $486,246 | 2,884,427 |
kWh
|
$0.17 | |
| Electricity Demand | $39,613 | 5,757 |
kW-mo/yr
|
$6.88 | |
| Natural Gas | $74,649 | 5,210 |
MMBtu
|
$14.33 | |
| Waste Disposal Costs | |||||
| Water Usage | $50,342 | 95 |
Tgal
|
$531.53 | |
| TOTAL YEARLY COSTS | $650,850 | ||||
| RECOMMENDED SAVINGS* | $380,774 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $137,524 | - |
$108,422
641,550
kWh
|
$29,102
-
kW-mo/yr
|
- | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $17,625 | - |
$16,346
96,720
kWh
|
$1,279
-
kW-mo/yr
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $66,793 | $10,200 |
$60,147
355,899
kWh
|
$6,646
-
kW-mo/yr
|
- | |
| 04 | 2.7135: Install occupancy sensors | $441 | $296 |
$441
2,610
kWh
|
- | - | |
| 05 | 2.2443: Re-use or recycle hot or cold process exhaust air | $9,257 | $7,500 | - | - |
$9,257
-
MMBtu
|
|
| 06 | 2.4221: Install compressor air intakes in coolest locations | $7,303 | $8,000 |
$6,573
38,869
kWh
|
$730
-
kW-mo/yr
|
- | |
| 07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $9,955 | $23,000 |
$8,964
53,040
kWh
|
$991
-
kW-mo/yr
|
- | |
| 08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $61,818 | $250,000 |
$55,668
329,402
kWh
|
$6,150
-
kW-mo/yr
|
- | |
| 09 | 2.6231: Utilize controls to operate equipment only when needed | $32,528 | $141,920 |
$28,821
170,897
kWh
|
$1,844
-
kW-mo/yr
|
$1,863
-
MMBtu
|
|
| 10 | 2.9112: Use solar heat to heat water | $37,530 | $282,800 |
$37,530
259,671
kWh
|
- | - | |
| TOTAL RECOMMENDED | $380,774 | $723,716 |
$322,912
1,948,658
kWh
|
$46,742
-
kW-mo/yr
|
$11,120
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs