Assessment Year | 2020 |
---|---|
Principal Product | Coffee, spices, Rice & Beans |
NAICS | 311920: Coffee and Tea Manufacturing |
SIC | 2095: Roasted Coffee |
Sales Range | $50 M to 100M |
# of Employees | 300 |
Plant Area |
250,000
ft2
|
Annual Production | 75,000,000
ton
|
Production Hrs. Annual | 8,650
hrs
|
Location (State) | South Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $344,635 | 7,641,399 |
kWh
|
$0.045 | |
Electricity Demand | $245,045 | 16,094 |
kW-mo/yr
|
$15.23 | |
Electricity Fees | $25,633 | - |
|
- | |
Natural Gas | $18,335 | 18,339 |
MMBtu
|
$1.00 | |
Waste Disposal Costs | |||||
Water Usage | $15,000 | 2,140 |
Tgal
|
$7.01 | |
Water Disposal | $57,300 | 2,140 |
Tgal
|
$26.78 | |
TOTAL YEARLY COSTS | $705,948 | ||||
RECOMMENDED SAVINGS* | $29,360 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $29,360 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,007 | $31,776 |
$7,177
159,495
kWh
|
$5,830
-
kW-mo/yr
|
|
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $670 | $5,393 |
$352
7,830
kWh
|
$318
-
kW-mo/yr
|
|
03 | 2.7221: Lower temperature during the winter season and vice-versa | $15,683 | - |
$15,683
348,500
kWh
|
- | |
TOTAL RECOMMENDED | $29,360 | $37,169 |
$23,212
515,825
kWh
|
$6,148
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $29,360 | $37,169 |
$23,212
515,825
kWh
|
$6,148
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs