| Assessment Year | 2026 |
|---|---|
| Principal Product | Rigid boxes and thermoformed trays |
| NAICS | 322211: Corrugated and Solid Fiber Box Manufacturing |
| SIC | 2653: Corrugated and Solid Fiber Boxes |
| Sales Range | $10 M to 50M |
| # of Employees | 53 |
| Plant Area |
90,000
ft2
|
| Annual Production | 19,795,711
units
|
| Production Hrs. Annual | 2,600
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $139,974 | 1,896,755 |
kWh
|
$0.074 | |
| Electricity Demand | $72,751 | 8,274 |
kW-mo/yr
|
$8.79 | |
| Electricity Fees | $0.1 | - |
|
- | |
| Natural Gas | $19,710 | 1,800 |
MMBtu
|
$10.95 | |
| Waste Disposal Costs | |||||
| Water Usage | $8,621 | 236 |
Tgal
|
$36.53 | |
| TOTAL YEARLY COSTS | $241,056 | ||||
| RECOMMENDED SAVINGS* | $87,886 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7261: Install timers and/or thermostats | $1,262 | - |
$1,262
17,051
kWh
|
- | - | |
| 02 | 2.6222: Use drying oven (batch type) on alternate days or other optimum schedule to run equipment with full loads | $3,636 | $1,200 | - |
$3,636
-
kW-mo/yr
|
- | |
| 03 | 2.2428: Use flue gases in radiant heater for space heating, ovens, etc | $50,403 | $29,620 |
$41,015
554,252
kWh
|
$9,388
-
kW-mo/yr
|
- | |
| 04 | 2.2443: Re-use or recycle hot or cold process exhaust air | $843 | $950 | - | - |
$843
-
MMBtu
|
|
| 05 | 2.7135: Install occupancy sensors | $71 | $140 |
$45
603
kWh
|
$26
-
kW-mo/yr
|
- | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $958 | $2,000 |
$916
12,376
kWh
|
$42
-
kW-mo/yr
|
- | |
| 07 | 2.2428: Use flue gases in radiant heater for space heating, ovens, etc | $1,313 | $2,200 |
$847
11,440
kWh
|
$466
-
kW-mo/yr
|
- | |
| 08 | 2.2622: Replace existing chiller with high efficiency model | $3,592 | $22,000 |
$2,852
38,551
kWh
|
$740
-
kW-mo/yr
|
- | |
| 09 | 2.4226: Use / purchase optimum sized compressor | $11,046 | $45,405 |
$5,772
78,000
kWh
|
$5,274
-
kW-mo/yr
|
- | |
| 10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,316 | $6,093 |
$850
11,492
kWh
|
$466
-
kW-mo/yr
|
- | |
| 11 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $5,064 | $24,000 |
$3,271
44,200
kWh
|
$1,793
-
kW-mo/yr
|
- | |
| 12 | 2.4221: Install compressor air intakes in coolest locations | $1,333 | $7,000 |
$1,175
15,882
kWh
|
$158
-
kW-mo/yr
|
- | |
| 13 | 2.7232: Replace existing hvac unit with high efficiency model | $5,715 | $5,715 |
$5,126
69,264
kWh
|
$589
-
kW-mo/yr
|
- | |
| 14 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,105 | $12,000 |
$718
9,698
kWh
|
$387
-
kW-mo/yr
|
- | |
| 15 | 2.7312: Minimize use of outside make-up air for ventilation except when used for economizer cycle | $229 | $834 | - | - |
$229
-
MMBtu
|
|
| TOTAL RECOMMENDED | $87,886 | $159,157 |
$63,849
862,809
kWh
|
$22,965
-
kW-mo/yr
|
$1,072
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs