ITAC Assessment: LE0528
ITAC logo
ITAC Assessment: LE0528
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2022
Principal Product Sterilization Case
NAICS 339112: Surgical and Medical Instrument Manufacturing
SIC 3841: Surgical and Medical Instruments and Apparatus
Sales Range $10
M
to 50
M
# of Employees 40
Plant Area 60,000
ft2
Annual Production 80,000
units
Production Hrs. Annual 3,003
hrs
Location (State) New Jersey

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $64,360 522,468
kWh
Electricity Demand $15,367 2,426
kW-mo/yr
Electricity Fees $4,450 -
Natural Gas $19,811 2,757
MMBtu
TOTAL YEARLY COSTS $103,988
RECOMMENDED SAVINGS* $309,463 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $306,916

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Primary Product Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $1,359 $40 $1,125
9,144
kWh
$234
-
kW-mo/yr
- -
02 2.7261: Install timers and/or thermostats $2,953 $1,000 $1,910
15,578
kWh
- $1,043
-
MMBtu
-
03 2.4321: Upgrade obsolete equipment $150,000 $90,000 - - - $150,000
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,512 $150 $1,254
10,195
kWh
$258
-
kW-mo/yr
- -
05 2.4321: Upgrade obsolete equipment $150,000 $150,000 - - - $150,000
06 2.4221: Install compressor air intakes in coolest locations $1,188 $2,000 $986
8,012
kWh
$202
-
kW-mo/yr
- -
07 2.4322: Use or replace with energy efficient substitutes $2,451 $15,000 $2,033
16,526
kWh
$418
-
kW-mo/yr
- -
TOTAL RECOMMENDED $309,463 $258,190 $7,308
59,455
kWh
$1,112
-
kW-mo/yr
$1,043
-
MMBtu
$300,000
TOTAL IMPLEMENTED $306,916 $256,150 $5,197
42,299
kWh
$676
-
kW-mo/yr
$1,043
-
MMBtu
$300,000
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Primary Product Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs