Assessment Year 2017
Principal Product Processed Foods
NAICS 311421: Fruit and Vegetable Canning
SIC 2033: Canned Fruits, Vegetables, Preserves, Jams, and Jellies
Sales Range $100
M
to 500
M
# of Employees 450
Plant Area 150,000
ft2
Annual Production 25,000,000
units
Production Hrs. Annual 8,736
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,161,263 19,870,720
kWh
Electricity Demand $145,312 36,156
kW-mo/yr
Electricity Fees $101,645 -
Natural Gas $1,770,657 360,854
MMBtu
TOTAL YEARLY COSTS $3,178,877
RECOMMENDED SAVINGS* $617,407 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings
01 2.7261: Install timers and/or thermostats $1,292 $44 $344
5,933
kWh
$948
-
kW-mo/yr
- -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $7,615 $1,000 $6,924
119,381
kWh
$691
-
kW-mo/yr
- -
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $724 $300 $664
11,445
kWh
$60
-
kW-mo/yr
- -
04 2.4221: Install compressor air intakes in coolest locations $4,684 $4,000 $4,134
71,268
kWh
$551
-
kW-mo/yr
- -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $26,653 $31,212 $24,337
419,608
kWh
$2,316
-
kW-mo/yr
- -
06 2.4226: Use / purchase optimum sized compressor $35,515 $53,000 $32,287
556,665
kWh
$3,228
-
kW-mo/yr
- -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $40,926 $75,373 $37,368
644,280
kWh
$3,558
-
kW-mo/yr
- -
08 2.1224: Replace boiler $397,300 $900,000 - - $147,300
-
MMBtu
$250,000
09 2.7312: Minimize use of outside make-up air for ventilation except when used for economizer cycle $9,040 $22,500 $(-1,393.0)
(-24,024)
kWh
$(-132.6)
-
kW-mo/yr
$10,566
-
MMBtu
-
10 2.4226: Use / purchase optimum sized compressor $18,899 $58,000 $16,961
292,432
kWh
$1,938
-
kW-mo/yr
- -
11 2.1233: Analyze flue gas for proper air/fuel ratio $16,503 $54,000 - - $16,503
-
MMBtu
-
12 2.7142: Utilize higher efficiency lamps and/or ballasts $2,262 $8,160 $1,900
32,760
kWh
$362
-
kW-mo/yr
- -
13 2.2443: Re-use or recycle hot or cold process exhaust air $53,347 $200,000 - - $53,347
-
MMBtu
-
14 2.7142: Utilize higher efficiency lamps and/or ballasts $337 $1,488 $256
4,420
kWh
$80
-
kW-mo/yr
- -
15 2.7232: Replace existing hvac unit with high efficiency model $2,312 $10,220 $2,111
36,400
kWh
$201
-
kW-mo/yr
- -
TOTAL RECOMMENDED $617,407 $1,419,297 $125,892
2,170,568
kWh
$13,799
-
kW-mo/yr
$227,716
-
MMBtu
$250,000
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs