Assessment Year | 2016 |
---|---|
Principal Product | Asphalt Products |
NAICS | 324122: Asphalt Shingle and Coating Materials Manufacturing |
SIC | 2952: Asphalt Felts and Coatings |
Sales Range | $1 M to 5M |
# of Employees | 15 |
Plant Area |
70,000
ft2
|
Annual Production | 45,000
ton
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $478,381 | 5,634,214 |
kWh
|
$0.085 |
Electricity Demand | $90,774 | 15,976 |
kW-mo/yr
|
$5.68 |
Natural Gas | $1,129,299 | 187,247 |
MMBtu
|
$6.03 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $470,268 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $97,020 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $34,913 | $25 |
$34,913
410,739
kWh
|
- | - | - | |
02 | 2.2113: Repair or replace steam traps | $28,076 | $1,125 | - | - |
$28,076
-
MMBtu
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $12,093 | $1,000 |
$11,003
129,443
kWh
|
$1,091
-
kW-mo/yr
|
- | - | |
04 | 2.7261: Install timers and/or thermostats | $190 | $25 |
$46
538
kWh
|
- |
$145
-
MMBtu
|
- | |
05 | 2.2443: Re-use or recycle hot or cold process exhaust air | $293,975 | $56,000 | - | - |
$293,975
-
MMBtu
|
- | |
06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $11,005 | $4,800 | - | - |
$11,005
-
MMBtu
|
- | |
07 | 2.2414: Use waste heat from hot flue gases to preheat | $10,070 | $10,080 | - | - |
$10,070
-
MMBtu
|
- | |
08 | 2.4226: Use / purchase optimum sized compressor | $69,013 | $99,925 |
$63,208
743,628
kWh
|
$5,805
-
kW-mo/yr
|
- | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,933 | $45,975 |
$7,574
89,107
kWh
|
$1,392
-
kW-mo/yr
|
- | $1,967 | |
TOTAL RECOMMENDED | $470,268 | $218,955 |
$116,744
1,373,455
kWh
|
$8,287
-
kW-mo/yr
|
$343,270
-
MMBtu
|
$1,967 | ||
TOTAL IMPLEMENTED | $97,020 | $52,925 |
$53,490
629,289
kWh
|
$2,482
-
kW-mo/yr
|
$39,081
-
MMBtu
|
$1,967 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs