Assessment Year 2014
Principal Product Siliconized Release Film
NAICS 326113: Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing
SIC 3081: Unsupported Plastics Film and Sheet
Sales Range $50
M
to 100
M
# of Employees 20
Plant Area 208,000
ft2
Annual Production 9,500
ton
Production Hrs. Annual 6,120
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $501,757 8,775,132
kWh
Electricity Demand $55,078 15,428
kW-mo/yr
Electricity Fees $29,002 -
Natural Gas $190,329 41,250
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $159,741 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $49,870

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,983 - $3,547
62,230
kWh
$436
-
kW-mo/yr
-
02 2.2628: Utilize a less expensive cooling method $35,793 $130,000 $35,793
627,955
kWh
- -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,233 $1,000 $2,837
49,767
kWh
$396
-
kW-mo/yr
-
04 2.7261: Install timers and/or thermostats $3,209 $1,225 $572
10,036
kWh
- $2,637
-
MMBtu
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $3,652 $2,400 $2,495
43,770
kWh
$1,157
-
kW-mo/yr
-
06 2.2442: Preheat combustion air with waste heat $9,750 $6,900 - - $9,750
-
MMBtu
07 2.1224: Replace boiler $93,869 $72,460 - - $93,869
-
MMBtu
08 2.7142: Utilize higher efficiency lamps and/or ballasts $4,176 $4,410 $3,705
65,000
kWh
$471
-
kW-mo/yr
-
09 2.7232: Replace existing hvac unit with high efficiency model $681 $1,400 $606
10,625
kWh
$75
-
kW-mo/yr
-
10 2.4221: Install compressor air intakes in coolest locations $1,395 $4,250 $1,070
18,779
kWh
$325
-
kW-mo/yr
-
TOTAL RECOMMENDED $159,741 $224,045 $50,625
888,162
kWh
$2,860
-
kW-mo/yr
$106,256
-
MMBtu
TOTAL IMPLEMENTED $49,870 $134,625 $45,244
793,758
kWh
$1,988
-
kW-mo/yr
$2,637
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs