Assessment Year 2013
Principal Product Electronic Components
NAICS 334419: Other Electronic Component Manufacturing
SIC 3679: Electronic Components, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 15
Plant Area 45,300
ft2
Annual Production 2,000,000
pieces
Production Hrs. Annual 8,736
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $748,641 11,178,700
kWh
Electricity Demand $86,097 18,970
kW-mo/yr
Electricity Fees $50,649 -
Natural Gas $35,671 3,330
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $120,533 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $1,192 $1,280 $1,192
17,792
kWh
- - -
02 2.2625: Chill water to the highest temperature possible $10,077 $800 $9,219
137,592
kWh
$858
-
kW-mo/yr
- -
03 2.2625: Chill water to the highest temperature possible $15,354 $800 $14,047
209,664
kWh
$1,307
-
kW-mo/yr
- -
04 2.4111: Utilize energy-efficient belts and other improved mechanisms $72 $72 $66
980
kWh
$6
-
kW-mo/yr
- -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,200 $1,000 $2,014
30,065
kWh
$186
-
kW-mo/yr
- -
06 2.7261: Install timers and/or thermostats $4,569 $4,320 $17
248
kWh
- $4,552
-
MMBtu
-
07 2.4221: Install compressor air intakes in coolest locations $618 $500 $568
8,476
kWh
$50
-
kW-mo/yr
- -
08 2.4226: Use / purchase optimum sized compressor $688 $1,200 $588
8,776
kWh
$100
-
kW-mo/yr
- -
09 2.8113: Purchase gas directly from a contract gas supplier $12,354 - - - - $12,354
10 2.7142: Utilize higher efficiency lamps and/or ballasts $38,761 $61,150 $36,863
550,193
kWh
$1,898
-
kW-mo/yr
- -
11 2.7232: Replace existing hvac unit with high efficiency model $9,665 $16,200 $8,780
131,040
kWh
$885
-
kW-mo/yr
- -
12 2.7232: Replace existing hvac unit with high efficiency model $21,154 $64,400 $17,604
262,752
kWh
$3,550
-
kW-mo/yr
- -
13 2.1311: Replace electrically-operated equipment with fossil fuel equipment $3,829 $2,000 $7,009
104,625
kWh
- $(-3,180.0)
-
MMBtu
-
TOTAL RECOMMENDED $120,533 $153,722 $97,967
1,462,203
kWh
$8,840
-
kW-mo/yr
$1,372
-
MMBtu
$12,354
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs