Assessment Year | 2012 |
---|---|
Principal Product | Auto Parts |
NAICS | 423120: Motor Vehicle Supplies and New Parts Merchant Wholesalers |
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $100 M to 500M |
# of Employees | 350 |
Plant Area |
342,000
ft2
|
Annual Production | 500,000
pieces
|
Production Hrs. Annual | 6,552
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $294,019 | 3,648,974 |
kWh
|
$0.081 |
Natural Gas | $93,426 | 13,326 |
MMBtu
|
$7.01 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $137,330 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $9,181 | $8,250 |
$9,181
120,797
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $32,208 | $54,225 |
$32,208
416,864
kWh
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $953 | $1,000 |
$953
12,543
kWh
|
- | |
04 | 2.7261: Install timers and/or thermostats | $26,676 | - |
$26,676
351,000
kWh
|
- | |
05 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $5,033 | $5,527 | - |
$5,033
-
MMBtu
|
|
06 | 2.7425: Clean or color roof to reduce solar load | $10,053 | $13,598 |
$10,053
127,895
kWh
|
- | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,391 | $1,900 |
$1,391
18,307
kWh
|
- | |
08 | 2.7261: Install timers and/or thermostats | $16,632 | $3,000 |
$4,385
57,693
kWh
|
$12,247
-
MMBtu
|
|
09 | 2.7232: Replace existing hvac unit with high efficiency model | $3,535 | $21,000 |
$2,974
39,137
kWh
|
$561
-
MMBtu
|
|
10 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,096 | $12,800 |
$3,096
40,732
kWh
|
- | |
11 | 2.4221: Install compressor air intakes in coolest locations | $586 | $800 |
$586
7,713
kWh
|
- | |
12 | 2.7135: Install occupancy sensors | $16,429 | $30,000 |
$16,429
213,169
kWh
|
- | |
13 | 2.7124: Make a practice of turning off lights when not needed | $9,090 | - |
$9,090
119,600
kWh
|
- | |
14 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $262 | $520 |
$262
3,450
kWh
|
- | |
15 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,205 | $10,010 |
$2,205
28,304
kWh
|
- | |
TOTAL RECOMMENDED | $137,330 | $162,630 |
$119,489
1,557,204
kWh
|
$17,841
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs