| Assessment Year | 2005 |
|---|---|
| Principal Product | Aluminum Lids |
| NAICS | 332431: Metal Can Manufacturing |
| SIC | 2096: Potato Chips, Corn Chips, and Similar Snacks |
| Sales Range | $50 M to 100M |
| # of Employees | 118 |
| Plant Area |
200,500
ft2
|
| Annual Production | 1,000,000,000
pieces
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $536,322 | 12,860,529 |
kWh
|
$0.042 |
| Natural Gas | $56,363 | 10,322 |
MMBtu
|
$5.46 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $110,600 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $104,450 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4226: Use / purchase optimum sized compressor | $56,710 | $346,448 |
$45,100
1,392,900
kWh
|
$11,610
-
kW-mo/yr
|
- | - | |
| 02 | 2.6218: Turn off equipment when not in use | $26,550 | $89,981 |
$33,550
1,036,000
kWh
|
- | - | $(-7,000.0) | |
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,440 | $9,180 |
$1,520
47,000
kWh
|
$1,920
-
kW-mo/yr
|
- | - | |
| 04 | 2.4314: Use synthetic lubricant | $2,710 | $1,660 |
$1,470
45,500
kWh
|
$1,200
-
kW-mo/yr
|
- | $40 | |
| 05 | 2.6218: Turn off equipment when not in use | $820 | - |
$450
13,900
kWh
|
$370
-
kW-mo/yr
|
- | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $12,330 | $26,160 |
$8,460
261,400
kWh
|
$4,880
-
kW-mo/yr
|
$(-240.0) | $(-770.0) | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,040 | $26,010 |
$3,560
109,900
kWh
|
$4,600
-
kW-mo/yr
|
$220 | $(-340.0) | |
| TOTAL RECOMMENDED | $110,600 | $499,439 |
$94,110
2,906,600
kWh
|
$24,580
-
kW-mo/yr
|
$(-20.0) | $(-8,070.0) | ||
| TOTAL IMPLEMENTED | $104,450 | $488,599 |
$91,120
2,814,100
kWh
|
$21,460
-
kW-mo/yr
|
$(-20.0) | $(-8,110.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs