Assessment Year | 2008 |
---|---|
Principal Product | Elevator |
NAICS | 333921: Elevator and Moving Stairway Manufacturing |
SIC | 3534: Elevators and Moving Stairways |
Sales Range | $100 M to 500M |
# of Employees | 367 |
Plant Area |
300,000
ft2
|
Annual Production | 6,500
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $564,671 | 10,147,970 |
kWh
|
$0.056 |
Electricity Demand | $138,266 | 19,357 |
kW-mo/yr
|
$7.14 |
Natural Gas | $623,797 | 103,391 |
MMBtu
|
$6.03 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $264,658 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $103,151 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4321: Upgrade obsolete equipment | $94,158 | $132,748 |
$15,394
274,901
kWh
|
- | - |
$78,764
-
MMBtu
|
- | |
02 | 2.6218: Turn off equipment when not in use | $36,970 | $760 |
$2,298
41,030
kWh
|
- | - |
$34,672
-
MMBtu
|
- | |
03 | 2.7231: Use radiant heater for spot heating | $17,728 | $16,000 | - | - | - |
$17,728
-
MMBtu
|
- | |
04 | 2.7261: Install timers and/or thermostats | $12,408 | $9,600 |
$12,408
221,562
kWh
|
- | - | - | - | |
05 | 2.7312: Minimize use of outside make-up air for ventilation except when used for economizer cycle | $10,716 | $1,200 | - | - | $(-1,344.0) |
$12,060
-
MMBtu
|
- | |
06 | 2.7496: Install partitions to reduce size of conditioned space | $8,828 | $7,000 | - | - | - |
$8,828
-
MMBtu
|
- | |
07 | 2.2437: Recover waste heat from equipment | $6,783 | $7,000 | - | - | - |
$6,783
-
MMBtu
|
- | |
08 | 2.2211: Use optimum temperature | $7,669 | $500 | - | - | - |
$7,669
-
MMBtu
|
- | |
09 | 2.4231: Reduce the pressure of compressed air to the minimum required | $5,894 | $304 |
$4,694
83,826
kWh
|
$1,200
-
kW-mo/yr
|
- | - | - | |
10 | 2.4221: Install compressor air intakes in coolest locations | $3,764 | $800 |
$2,950
52,687
kWh
|
$814
-
kW-mo/yr
|
- | - | - | |
11 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,195 | $1,824 |
$2,545
45,443
kWh
|
$650
-
kW-mo/yr
|
- | - | - | |
12 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $2,387 | $3,290 | - | - | - |
$2,387
-
MMBtu
|
- | |
13 | 2.7261: Install timers and/or thermostats | $1,785 | $450 |
$1,785
31,882
kWh
|
- | - | - | - | |
14 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $52,373 | $142,010 |
$42,073
751,302
kWh
|
$10,731
-
kW-mo/yr
|
- | - | $(-431.0) | |
TOTAL RECOMMENDED | $264,658 | $323,486 |
$84,147
1,502,633
kWh
|
$13,395
-
kW-mo/yr
|
$(-1,344.0) |
$168,891
-
MMBtu
|
$(-431.0) | ||
TOTAL IMPLEMENTED | $103,151 | $152,044 |
$48,701
869,657
kWh
|
$11,381
-
kW-mo/yr
|
- |
$43,500
-
MMBtu
|
$(-431.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs