Assessment Year 2007
Principal Product corrugated packaging and displays
NAICS 322211: Corrugated and Solid Fiber Box Manufacturing
SIC 2653: Corrugated and Solid Fiber Boxes
Sales Range $10
M
to 50
M
# of Employees 205
Plant Area 198,500
ft2
Annual Production 45,000
ton
Production Hrs. Annual 6,000
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $245,274 5,440,762
kWh
Electricity Demand $130,887 13,705
kW-mo/yr
Natural Gas $882,539 56,123
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $549,400 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $486,319

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Increase in Production Savings
01 2.8113: Purchase gas directly from a contract gas supplier $433,831 $500 - - $433,831
-
MMBtu
-
02 4.424: Improve space comfort conditioning $44,000 $3,000 - - - $44,000
03 2.2113: Repair or replace steam traps $23,595 $5,000 - - $23,595
-
MMBtu
-
04 2.1233: Analyze flue gas for proper air/fuel ratio $19,641 $29,600 - - $19,641
-
MMBtu
-
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $9,252 $1,000 $6,495
144,330
kWh
$2,757
-
kW-mo/yr
- -
06 2.3131: Reschedule plant operations or reduce load to avoid peaks $9,146 $21,000 - $9,146
-
kW-mo/yr
- -
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $4,471 $1,500 $3,038
67,535
kWh
$1,433
-
kW-mo/yr
- -
08 2.7261: Install timers and/or thermostats $3,186 $420 $1,495
33,210
kWh
$1,691
-
kW-mo/yr
- -
09 2.4221: Install compressor air intakes in coolest locations $2,278 $2,500 $1,333
29,648
kWh
$945
-
kW-mo/yr
- -
TOTAL RECOMMENDED $549,400 $64,520 $12,361
274,723
kWh
$15,972
-
kW-mo/yr
$477,067
-
MMBtu
$44,000
TOTAL IMPLEMENTED $486,319 $36,100 $6,495
144,330
kWh
$2,757
-
kW-mo/yr
$477,067
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Increase in Production Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs