Assessment Year | 2005 |
---|---|
Principal Product | Wlelded Steel Tubing |
NAICS | 331210: Iron and Steel Pipe and Tube Manufacturing from Purchased Steel |
SIC | 3317: Steel Pipe and Tubes |
Sales Range | $10 M to 50M |
# of Employees | 290 |
Plant Area |
249,953
ft2
|
Annual Production | 151,803
thousand feet
|
Production Hrs. Annual | 6,120
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $469,024 | 8,712,000 |
kWh
|
$0.054 |
Electricity Demand | $148,797 | 23,952 |
kW-mo/yr
|
$6.21 |
Natural Gas | $674,655 | 91,796 |
MMBtu
|
$7.35 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $216,315 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $138,073 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.1224: Replace boiler | $109,438 | $9,760 | - | - |
$109,438
-
MMBtu
|
|
02 | 2.8113: Purchase gas directly from a contract gas supplier | $72,942 | $500 | - | - |
$72,942
-
MMBtu
|
|
03 | 2.4239: Eliminate or reduce compressed air usage | $21,328 | $8,300 |
$19,045
352,686
kWh
|
$2,283
-
kW-mo/yr
|
- | |
04 | 2.7261: Install timers and/or thermostats | $5,300 | $4,500 |
$5,300
87,027
kWh
|
- | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,115 | $1,000 |
$3,271
60,562
kWh
|
$1,844
-
kW-mo/yr
|
- | |
06 | 2.7261: Install timers and/or thermostats | $1,341 | $500 |
$702
9,900
kWh
|
- |
$639
-
MMBtu
|
|
07 | 2.4221: Install compressor air intakes in coolest locations | $851 | $500 |
$516
9,558
kWh
|
$335
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $216,315 | $25,060 |
$28,834
519,733
kWh
|
$4,462
-
kW-mo/yr
|
$183,019
-
MMBtu
|
||
TOTAL IMPLEMENTED | $138,073 | $20,060 |
$23,534
432,706
kWh
|
$4,462
-
kW-mo/yr
|
$110,077
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs