Assessment Year | 2003 |
---|---|
Principal Product | Hi-Tech Rubber Parts |
NAICS | 326121: Unlaminated Plastics Profile Shape Manufacturing |
SIC | 3082: Unsupported Plastics Profile Shapes |
Sales Range | $10 M to 50M |
# of Employees | 50 |
Plant Area |
44,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 4,680
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $88,789 | 759,290 |
kWh
|
$0.12 |
Electricity Demand | $12,501 | 1,069 |
kW-mo/yr
|
$11.69 |
Natural Gas | $14,025 | 1,116 |
MMBtu
|
$12.57 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $11,141 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,112 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $2,831 | $1,000 |
$2,082
21,245
kWh
|
$749
-
kW-mo/yr
|
- | |
02 | 2.7261: Install timers and/or thermostats | $5,145 | $1,050 |
$5,145
52,500
kWh
|
- | - | |
03 | 2.7261: Install timers and/or thermostats | $1,053 | $1,000 | - | - |
$1,053
-
MMBtu
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,082 | $100 |
$836
8,529
kWh
|
$246
-
kW-mo/yr
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,030 | $2,638 |
$664
6,771
kWh
|
$366
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $11,141 | $5,788 |
$8,727
89,045
kWh
|
$1,361
-
kW-mo/yr
|
$1,053
-
MMBtu
|
||
TOTAL IMPLEMENTED | $2,112 | $2,738 |
$1,500
15,300
kWh
|
$612
-
kW-mo/yr
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs