Assessment Year | 2003 |
---|---|
Principal Product | Optical Glasses |
NAICS | 327212: Other Pressed and Blown Glass and Glassware Manufacturing |
SIC | 3229: Pressed and Blown Glass and Glassware, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 400 |
Plant Area |
800,000
ft2
|
Annual Production | 3,500
ton
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,590,727 | 36,637,000 |
kWh
|
$0.043 |
Electricity Demand | $335,189 | 59,378 |
kW-mo/yr
|
$5.65 |
Natural Gas | $306,595 | 53,359 |
MMBtu
|
$5.75 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $33,707 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,271 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7135: Install occupancy sensors | $160 | $675 |
$160
3,676
kWh
|
- | - | |
02 | 2.7124: Make a practice of turning off lights when not needed | $1,934 | - |
$1,934
44,554
kWh
|
- | - | |
03 | 2.7111: Reduce illumination to minimum necessary levels | $457 | $54 |
$394
9,085
kWh
|
$63
-
kW-mo/yr
|
- | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,046 | - |
$731
16,848
kWh
|
$315
-
kW-mo/yr
|
- | |
05 | 2.2511: Insulate bare equipment | $7,291 | $1,138 |
$7,291
167,985
kWh
|
- | - | |
06 | 2.7444: Close holes and openings in building such as broken windows | $3,229 | $1,000 | - | - |
$3,229
-
MMBtu
|
|
07 | 2.4221: Install compressor air intakes in coolest locations | $13,777 | $1,500 |
$11,246
259,129
kWh
|
$2,531
-
kW-mo/yr
|
- | |
08 | 2.7447: Install vinyl strip / high speed / air curtain doors | $5,813 | $1,000 | - | - |
$5,813
-
MMBtu
|
|
TOTAL RECOMMENDED | $33,707 | $5,367 |
$21,756
501,277
kWh
|
$2,909
-
kW-mo/yr
|
$9,042
-
MMBtu
|
||
TOTAL IMPLEMENTED | $10,271 | $1,138 |
$9,956
229,387
kWh
|
$315
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs