Assessment Year | 2002 |
---|---|
Principal Product | Tools, Dies, Machinery |
NAICS |
n/a
|
SIC | 3544: Special Dies and Tools, Die Sets, Jigs and Fixtures, and Industrial Molds |
Sales Range | $5 M to 10M |
# of Employees | 19 |
Plant Area |
24,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,500
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $50,483 | 471,200 |
kWh
|
$0.11 |
Electricity Demand | $21,093 | 1,567 |
kW-mo/yr
|
$13.46 |
LPG | $7,200 | 510 |
MMBtu
|
$14.12 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $4,201 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,201 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings |
---|---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $642 | $500 |
$279
4,466
kWh
|
$363
-
kW-mo/yr
|
- | |
02 | 2.4323: Use optimum size and capacity equipment | $1,303 | $2,400 |
$1,303
20,883
kWh
|
- | - | |
03 | 2.7261: Install timers and/or thermostats | $2,256 | $1,050 | - | - |
$2,256
-
MMBtu
|
|
TOTAL RECOMMENDED | $4,201 | $3,950 |
$1,582
25,349
kWh
|
$363
-
kW-mo/yr
|
$2,256
-
MMBtu
|
||
TOTAL IMPLEMENTED | $4,201 | $3,950 |
$1,582
25,349
kWh
|
$363
-
kW-mo/yr
|
$2,256
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs