Assessment Year 1996
Principal Product Plastic Containers
NAICS
n/a
SIC 3085: Plastics Bottles
Sales Range $10
M
to 50
M
# of Employees 125
Plant Area 165,400
ft2
Annual Production 73,779,000
pieces
Production Hrs. Annual 8,472
hrs
Location (State) Missouri

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $737,870 15,104,631
kWh
Electricity Demand $76,677 25,179
kW-mo/yr
Natural Gas $50,016 11,105
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $60,611 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $38,341

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (non-haz) Savings Personnel Changes Savings Ancillary Material Cost Savings By-product Production Savings
01 2.4221: Install compressor air intakes in coolest locations $20,000 $1,833 $18,376
375,733
kWh
$1,624
-
kW-mo/yr
- - - - -
02 2.4133: Use most efficient type of electric motors $17,330 $15,534 $15,838
323,857
kWh
$1,492
-
kW-mo/yr
- - - - -
03 2.7111: Reduce illumination to minimum necessary levels $8,967 $4,716 $8,238
168,523
kWh
$729
-
kW-mo/yr
- - - - -
04 2.6231: Utilize controls to operate equipment only when needed $4,896 $1,208 - - $4,896
-
MMBtu
- - - -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $2,991 $4,551 $2,748
56,272
kWh
$243
-
kW-mo/yr
- - - - -
06 2.7135: Install occupancy sensors $2,927 $920 $2,689
55,100
kWh
$238
-
kW-mo/yr
- - - - -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $2,489 $4,140 $2,287
46,893
kWh
$202
-
kW-mo/yr
- - - - -
08 3.5315: Lease / purchase baler; sell cardboard to recycler $688 - - - - $188
-
lb
- - $500
09 2.7142: Utilize higher efficiency lamps and/or ballasts $323 $480 $130
2,638
kWh
$11
-
kW-mo/yr
- - $140 $42 -
TOTAL RECOMMENDED $60,611 $33,382 $50,306
1,029,016
kWh
$4,539
-
kW-mo/yr
$4,896
-
MMBtu
$188
-
lb
$140 $42 $500
TOTAL IMPLEMENTED $38,341 $17,847 $34,344
702,228
kWh
$3,127
-
kW-mo/yr
- $188
-
lb
$140 $42 $500
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (non-haz) Savings Personnel Changes Savings Ancillary Material Cost Savings By-product Production Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs