| Assessment Year | 1993 |
|---|---|
| Principal Product | AL. AND STEEL CANS |
| NAICS |
n/a
|
| SIC | 3411: Metal Cans |
| Sales Range | $50 M to 100M |
| # of Employees | 154 |
| Plant Area |
n/a
|
| Annual Production | 433,000,000
pieces
|
| Production Hrs. Annual | 6,264
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $440,694 | 10,917,937 |
kWh
|
$0.040 |
| Natural Gas | $235,311 | 110,548 |
MMBtu
|
$2.13 |
| Other Energy | $78,040 | 19,368 |
MMBtu
|
$4.03 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $78,999 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $14,287 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Other Energy Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.2425: Use flue gases to heat process or service water | $45,950 | $48,000 | - |
$(-18,390.0)
-
MMBtu
|
$64,340
-
MMBtu
|
- | |
| 02 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $17,158 | $19,000 |
$2,827
70,047
kWh
|
- | - | $14,331 | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $3,620 | $2,000 |
$3,620
89,683
kWh
|
- | - | - | |
| 04 | 2.4133: Use most efficient type of electric motors | $1,875 | $2,875 |
$1,875
46,600
kWh
|
- | - | - | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $7,003 | $19,646 |
$7,003
173,505
kWh
|
- | - | - | |
| 06 | 2.6127: Maintain air filters by cleaning or replacement | $1,349 | $700 |
$1,349
33,411
kWh
|
- | - | - | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $340 | - |
$450
11,137
kWh
|
- | - | $(-110.0) | |
| 08 | 2.7134: Use photocell controls | $835 | $400 |
$835
20,809
kWh
|
- | - | - | |
| 09 | 2.7135: Install occupancy sensors | $769 | $1,260 |
$769
19,050
kWh
|
- | - | - | |
| 10 | 2.6121: Reduce hot water temperature to the minimum required | $100 | $10 | - |
$100
-
MMBtu
|
- | - | |
| TOTAL RECOMMENDED | $78,999 | $93,891 |
$18,728
464,242
kWh
|
$(-18,290.0)
-
MMBtu
|
$64,340
-
MMBtu
|
$14,221 | ||
| TOTAL IMPLEMENTED | $14,287 | $25,231 |
$14,297
354,336
kWh
|
$100
-
MMBtu
|
- | $(-110.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Other Energy Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs